Learn how to fill and cap your Kera Cartridge by following the steps below.

Kera
Filling
Instructions

Learn how to fill and
cap your Kera Cartridge
by following the
steps below.

Kera

Filling & Capping Instructions

Filling the Reservoir

Insert the syringe blunt tip needle (14 ga. or smaller) into the space between the airway and the outer wall of the reservoir. With the device held upright, fill the reservoir with 0.5mL/1.0mL of oil.

Note: The syringe and needle may need to be warmed to improve fluid flow.

Do not allow fluid to enter the airway (center tube) as it may cause a short circuit.

Capping the Cartridge

Immediately after filling, snap-fit the mouthpiece until fully seated.

Failure to install the mouthpiece within 2 minutes of filling may result in leakage.

The recommended pressure for the snap-fit is 210lbf.

Allow For Headspace

Cartridges should stand for at least 30 minutes before use to allow the atomizer to saturate. More viscous fluids require more time. After a cartridge is filled, the atomizer begins to absorb the oil. Due to its large size and porous ceramic wick, a CCELL® atomizer can absorb up to 0.15mL (30%) of a 0.5mL cartridge. As the atomizer absorbs oil, headspace forms. Oil is still in the cartridge, but it's absorbed out of view.

Do not use for or refill with tobacco derived products.​

When cleaning the outer wall of the cartridge, use <75% isopropyl alcohol to avoid fogging.​

Previous slide
Next slide

Kera

Filling & Capping Instructions

Filling the Reservoir

Insert the syringe (blunt tip needle 14 ga. or smaller) into the space between the airway and the outer wall of the reservoir. With the device held upright, fill the reservoir with 0.5mL/1.0mL of oil.

Note: The syringe and needle may need to be warmed to improve fluid flow.

Do not overfill or allow oil to enter the center airway.

Capping the Cartridge

Immediately after filling, insert and press-fit the mouthpiece until it is fully seated. Mechanical assistance, such as an arbor press or channel lock pliers, is required to fully seat the mouthpiece.

Failure to install the mouthpiece within 2 minutes of filling may result in leakage.

Allow for headspace

Cartridges should stand for at least 30 minutes before use to allow the atomizer to saturate. More viscous fluids require more time. After a cartridge is filled, the atomizer begins to absorb the oil. Due to its large size and porous ceramic wick, a CCELL® atomizer can absorb up to 0.15mL (30%) of a 0.5mL cartridge. As the atomizer absorbs oil, headspace forms. Oil is still in the cartridge, but it's absorbed out of view.

Do not use for or refill with tobacco derived products.​

When cleaning the outer wall of the cartridge, use <75% isopropyl alcohol to avoid fogging​.

FAQ

Frequently Asked Questions

Jupiter Research partners with licensed extractors, growers, and producers that fill, seal, and deliver Liquid6™ Cartridges to licensed retailers.

No. Liquid6™ Cartridges are designed for single-use only.

It depends. Many variables affect how many activations an individual cartridge can provide. Factors include the duration of inhalation and the type of plant-derived extract.

Our cartridges vaporize oil at a consistent rate of 5mg per 3-second draw. Based on this level of consumption, a 0.5mL cartridge would last about 100 draws.

  1. Cartridge is empty when vapor is no longer produced after activation. Due to headspace, the cartridge may still produce vapor after the reservoir appears empty due to out of view oil absorbed in the atomizer.

CCELL® Cartridges are compatible with all Liquid6™ Power Supplies. CCELL® Cartridges feature a standard 510 thread connection found in many non-Jupiter power supplies and also include two airflow paths for auto-draw and button-activated power supplies.

Despite these considerations, we cannot guarantee cartridge compatibility with non-Jupiter power supplies.

If no draw-activation occurs, try the following: 

  • Make sure Power Supply is charged. 
  • Rotate mouthpiece to ensure positive connection between the Cartridge and Power Supply.
  • Separate the Cartridge from the Power Supply, then clean the contact points in the device and the bottom of the cartridge with a cotton swab dipped in a small amount of rubbing alcohol. 

If your product is within the warranty period and is not working properly, return the device, with the receipt, to the retailer where you purchased it. 

No. Jupiter Cartridges and Power Supplies are not to be used for tobacco-derived products.

  1. All cartridges may leak when transported from a lower elevation to a higher elevation. The degree of leakage depends on how full the cartridge is, how large the increase in elevation is, and the speed at which the elevation changes.

    To prevent leakage, store the cartridge with the mouthpiece pointing downward.

U.S. Federal Aviation Regulations dictate transport or use of substances and pharmaceuticals. Visit the Federal Aviation Administration website for more information.