Klik
Filling & Capping Instructions
Learn how to fill and cap your Klik Dispenser by following the steps below.
![](https://www.jupiterresearch.com/wp-content/uploads/2023/08/Jupiter_Klik_CallOuts_02-1024x295.png)
![](https://www.jupiterresearch.com/wp-content/uploads/2023/08/Jupiter_Klik_FillInstruction_Images-01-scaled.jpg)
Filling the Dispenser
Insert the syringe blunt tip needle into the open end of the Klik dispenser. With the dispenser held upright, fill the dispenser with up to a measured 1.5mL of oil.Note: The syringe and needle may need to be warmed to improve fluid flow.
Use a short blunt tipped needle (≤14ga.)
![](https://www.jupiterresearch.com/wp-content/uploads/2023/08/Jupiter_Klik_FillInstruction_Images-02-scaled.jpg)
Capping the Dispenser Tip
After filling, insert and press-fit the dispensing tip until it is fully seated. Mechanical assistance, such as an arbor press or channel lock pliers, are required to fully seat the mouthpiece.Do not use a hammer or mallet.
![](https://www.jupiterresearch.com/wp-content/uploads/2023/08/Jupiter_Klik_FillInstruction_Images-03-scaled.jpg)
Adjusting the Oil Level
If the dispenser is filled with less than 1.5mL, turn the dial until the top of the liquid is at the Max Fill Line.![](https://www.jupiterresearch.com/wp-content/uploads/2023/08/Jupiter_Klik_FillInstruction_Images-04-scaled.jpg)
Capping the Klik
Install the cap once oil level is at desired height.When cleaning the outer wall of the dispenser, use <75% isopropyl alcohol to avoid fogging.
Filling the Dispenser
![](https://www.jupiterresearch.com/wp-content/uploads/2023/08/Jupiter_Klik_FillInstruction_Images-01-scaled.jpg)
Insert the syringe blunt tip needle (14 ga. or smaller) into the open end of the Klik dispenser. With the dispenser held upright, fill the disenser with up to a measured 1.5mL of oil.
Note: The syringe and needle may need to be warmed to improve fluid flow.
Do not fill above the top of the main reservoir.
Capping the Dispenser Tip
![](https://www.jupiterresearch.com/wp-content/uploads/2023/08/Jupiter_Klik_FillInstruction_Images-02-scaled.jpg)
After filling, insert and press-fit the dispensing tip until it is fully seated. Mechanical assistance, such as an arbor press or channel lock pliers, are required to fully seat the mouthpiece.
Note: The syringe and needle may need to be warmed to improve fluid flow.
Do not overfill or allow oil to enter the center airway.
Adjusting the Oil Level
![](https://www.jupiterresearch.com/wp-content/uploads/2023/08/Jupiter_Klik_FillInstruction_Images-03-scaled.jpg)
If the dispenser is filled with less than 1.5mL, turn the dial until the top of the liquid is at the Max Fill Line.
Capping the Klik
![](https://www.jupiterresearch.com/wp-content/uploads/2023/08/Jupiter_Klik_FillInstruction_Images-04-scaled.jpg)
Install the cap once oil level is at desired height.
When cleaning the outer wall of the dispenser, use <75% isopropyl alcohol to avoid fogging.
FAQ
Frequently Asked Questions
Klik be used with high viscosity oils and CBD for eating, or as a dab applicator.
Klik is compatible with distillate cut with terpenes.
The syringe body is polypropylene, the plunger is silicone, and the tip is Ni-plated brass.