Sima
Filling Instructions

Learn how to fill and cap your Sima
All-In-One device.

Sima
Filling
Instructions

Learn how to fill and
cap your Sima
All-In-One device.

Sima

Fill Instructions

Filling the Reservoir

Fill a syringe with a short, blunt tipped needle (14 ga. or smaller) with oil. Insert the needle into the space between the airway and the outer walls of the cartridge reservoir. Fill both sides of the cartridge with 1.0mL of oil (0.5mL for each side).

Note: The syringe and needle may need to be warmed to improve fluid flow.

Do not allow fluid to enter the airway (center tube) as it may cause a short circuit.

Capping the Cartridge

Place the mouthpiece on top of the device, align to the device walls, and press the mouthpiece in until proper closure.

Failure to install the mouthpiece within 1 minute of filling may result in leakage.

Allow For Headspace

Check that the mouthpiece is pressed in completely and properly.

Device should be allowed to stand for at least 30 minutes before use. During this time, fluid is priming the atomizer. The rate that the atomizer saturates is dependent upon the viscosity of the fluid. More viscous fluids may require more time.

If the device is to experience a pressure change as a result of an increase in temperature or a change in elevation, the device must be shipped with the mouthpiece facing down, allowing for the inlets to be exposed to ambient air. ​

Previous slide
Next slide

Sima

Filling & Capping Instructions

Filling the Reservoir

Insert the syringe (blunt tip needle 14 ga. or smaller) into the space between the airway and the outer wall of the reservoir. With the device held upright, fill both sides of the cartridge with 1.0mL of oil (0.5mL for each side).

Note: The syringe and needle may need to be warmed to improve fluid flow.

Do not overfill or allow oil to enter the center airway.

Capping the Cartridge

Place the mouthpiece on top of the device, align to the device walls, and press the mouthpiece in until proper closure.

Failure to install the mouthpiece within 2 minutes of filling may result in leakage.

Allow for headspace

All-In-Ones should stand for at least 30 minutes before use to allow the atomizer to saturate. More viscous fluids require more time. After a cartridge is filled, the atomizer begins to absorb the oil. Due to its large size and porous ceramic wick, a CCELL® atomizer can absorb up to 0.15mL (30%) of a 0.5mL cartridge. As the atomizer absorbs oil, headspace forms. Oil is still in the cartridge, but it's absorbed out of view.

All-In-One vaporizers are expendable vaporizers for single-use only​.

When cleaning the outer wall of the cartridge, use <75% isopropyl alcohol to avoid fogging.

If the device is to experience a pressure change as a result of an increase in temperature or a change in elevation, the device must be shipped with the mouthpiece facing down, allowing for the inlets to be exposed to ambient air

FAQ

Frequently Asked Questions

It depends on whether or not you have a rechargeable All-In-One vaporizer. Now that we offer larger capacity All-In-One devices, we have added a rechargeable feature to ensure every puff is accounted for. Enjoy!

It depends. Many variables affect how many activations an individual cartridge can provide. Factors include the duration of inhalation and the type of plant-derived extract.

Our cartridges vaporize oil at a consistent rate of 5mg per 3-second draw. Based on this level of consumption, a 0.5mL cartridge would last about 100 draws.

All-In-Onescontains an oversized battery to ensure full vaporization of the extract before disposal. Battery life depends on how long and how often the device is in use.

All Jupiter Research vaporizers shut off after 10 seconds of inhalation.

Contact Our Team